Exhaust by-pass valve not working correctly
Fault codes Dds: exvl diagnosis -> position error, potentiometer, short circuit to ground or open circuit (s.C. Gnd or c.O.), Potentiometer short circuited to vdc (potentiometer s.C vdc). Dashboard: the error "exvl" (exhaust bypass valve) is shown on the service display. The eobd warning ...

Horn not working
Fault codes Dds: horn diagnosis -> short circuit to ground (s.C. Gnd). Dashboard: the error "claxon" (horn) is shown on the service display. The eobd warning light activates. Wiring diagram Db dashboard connection, s horn button. 5 Blue/white - b/w, 1 red/blue - r/b, db 19 purple/bl ...

Key-on/key-off using the red key on the handlebar with the passive key
A key-on can be performed by pressing the red button (6) on the handlebar in the hands free on/off position and in the presence of the passive key (4, fig. 77). Note The passive key (4, fig. 77) Has a range of a few cm, therefore the key (4, fig. 77) Must be positioned near the antenna (2). R ...