Unscrew the screws (1) and separate the connecting rods from the crankshaft.

Important

Take care not to mix up components of different connecting rods and maintain the original orientation.

Disassembly of the crankshaft/connecting rods assembly


Removal of the crankshaft/connecting rods assembly
After separating the crankcase halves, withdraw the crankshaft (6) complete with connecting rods (2). ...

Overhaul of the connecting rods
Make the following dimensional checks on the connecting rods: Clearance with gudgeon pin on assembly. In the event of excessive wear (sect. 3 - 1.1, Crankshaft), replace the connecting rod. ...

Other materials:

Reassembling the frame and the lateral footrests
Apply the recommended grease to the thread of the pins (9) and of the nuts (8). Place the frame (1) and the brackets (2) and (3) on the engine block. Start the pins (9) by holding the nuts (8) and insert without tightening the screws (6) into the adjusters (4). Position and fix the rear s ...

First warning - oil service 1000 km
The first warning is activated at 1000 km (600 miles) of odometer reading. The (red) warning is activated as a large icon for 10 seconds upon every key-on (1) then as a small warning that remains displayed (2) until it is reset. ...

Alternator
It is equipped with a 12 v, 430 w generator, consisting of a fixed element (stator, a) located on the generator cover and of a movable element (rotor, b) fixed to the crankshaft. Note To check the battery charging system for faults, use the dds diagnosis instrument and follow the instruct ...