Loosen the clamp (38) that retains the silencer (4) to the complete exhaust system.

Removing the silencer


While holding the nut (8), loosen the screw (1) and remove the silencer (4) from the motorcycle.

Removing the silencer


Loosen the screws (40) and remove the silencer guard (41).

Removing the silencer


Exhaust system
Screw Bush Vibration damper mount Silencer Washer Screw Bracket Nut Nut Upper heat guard Screw Washer Central heat guard Spacer Clip nut Long exhaust spring Plug ...

Removal of the exhaust system
Remove the silencer, as described in the paragraph "removing the silencer" of this section. Loosen the screws (28) and remove the exhaust by-pass valve cover (27). Turn the exhaust valve pul ...

Other materials:

Refitting the crankshaft/connecting rod assembly
Install the connecting rod assembly (6) and (2) in the crankcase, carry out the shimming and crankcase half reassembly procedure as described in sect. 9 - 9.2, Reassembly of the crankcase halves. Important Make sure that the connecting rods (2) are correctly positioned in the cylinders. Incor ...

Refitting the camshafts
If the stud bolts (2) were removed, apply the recommended threadlocker to the short end of the stud bolts (2), i.E. The end that is to be screwed into the cylinder head. Tighten the stud bolts (2) to a torque of 10 nm (min. 9 Nm - max. 11 Nm) (sect. 3 - 3, Engine torque settings). Check t ...

Guided diagnosis
Note The on-screen icons used during this procedure are explained in a table at the end of this section. The dds diagnosis instrument guides the operator step-by-step through the various diagnostic procedures, providing descriptions and documentation for motorcycle components, wiring diagra ...

2024 | www.dudiavel.com |